esp8266烧了mqtt的固件,怎么判断它能使用mqtt

创建于:2025年4月26日

使用 O3 回答 Chat01

问题

esp8266烧了mqtt的固件,怎么判断它能使用mqtt

思考

Providing MQTT check steps

To verify if the ESP8266 with MQTT firmware works, you can check it in a few ways. First, ensure that the firmware is correctly flashed. Then, you can connect the module to Wi-Fi. After creating a connection, use tools like mosquitto_sub or mosquitto_pub to test subscription and publishing to an MQTT broker. If you're using AT firmware, try sending AT commands via the serial monitor. Lastly, check log messages and monitor the serial output for potential errors.

Thought for a few seconds

回答

下面给你几种最简单也最可靠的方法,用来确认 ESP8266 在刷入带 MQTT 功能的固件后,确实已经能正常连上 MQTT 服务器并收发消息。
(以下假设你已经把 ESP8266 连上了本地 Wi-Fi,并知道它要去连的 MQTT Broker 的地址、端口、用户名和密码。)


1. 观察串口调试信息(首选法)

  1. 把 ESP8266 接到串口工具

    • 典型波特率 74880 或 115200(取决于固件)
    • 打开终端(PuTTY、CoolTerm、Arduino Serial Monitor 等)
  2. 上电或软重启
    固件若内建 MQTT 客户端,启动时通常会打印类似

    text
    Connecting to WiFi... WiFi connected: 192.168.1.50 Connecting to MQTT... MQTT Connected Subscribing /test/topic ...

    如果你能看到 “MQTT Connected” 或 return code = 0,就说明握手成功,固件确实在跑 MQTT。

  3. 本地回环测试

    • 在另一台电脑用 mosquitto_pub 往某个主题(如 /esp/test)发消息
    • 观察串口里是否立即打印收到的 payload。
      订阅/发布都没问题就 100 % 确认了。

2. 用命令行工具做双向验证

需要 PC 端已装好 Mosquitto CLI(或其他 MQTT 客户端)

bash
# ① 打开订阅端终端 mosquitto_sub -h 192.168.1.50 -t /esp/echo -v # ② 在 ESP8266 上的应用里把传感器数据 publish 到 /esp/echo # 串口会显示 “Publish ok” # ③ PC 端终端应该同步显示 payload

随后再反向测试:

bash
mosquitto_pub -h 192.168.1.50 -t /esp/cmd -m "LED_ON"

如果 ESP8266 能马上响应(亮 LED 或串口打印),说明发布-订阅链路都通。


3. 让 Broker 日志来证明

如果你用的是本地 Mosquitto:

  1. 编辑 /etc/mosquitto/mosquitto.confconnection_messages true 打开。
  2. 重启 Mosquitto,再让 ESP8266 连接一次。
  3. 在 Broker 端你会看到
    New client connected from 192.168.1.50 as esp8266-123456 (p2, c1, k60).
    
    这就是服务器侧的佐证。

4. 用 MQTT Dashboard/手机 App 快速肉眼确认

  • Android:MQTT Dash、IoT MQTT Panel
  • iOS:MQTT Explorer、EasyMQTT
    只要把 Broker、端口、用户密码填进去,APP 上能实时看到 ESP8266 发布的数据并且能下发指令,说明一切正常。

5. 常见排查要点(万一连不上)

项目典型症状解决思路
Wi-Fi 没连好串口反复打印 Connecting...核对 SSID/密码、信号强度
端口不对/被防火墙挡无法握手,错误 RC = 5确保 Broker 在 1883(或你设的端口)且防火墙已放行
TLS/SSL 配置不匹配握手失败、证书错误统一用非加密 1883 先排错,再上 8883/SSL
Client ID、用户名冲突server kick 掉旧连接改唯一 ID 或关闭 “clean session”

一句话总结

只要能在串口里或 Broker/App 里看到 “MQTT Connected” + 成功的收发,就证明固件的 MQTT 功能是 OK 的。

按上面任何一种方法验证通过,你就可以放心把业务逻辑往 ESP8266 里加了。祝调试顺利!

问题

烧了固件就能用了吗

思考

Thought for a couple of seconds

回答

不一定。
把 ESP8266 的 MQTT 固件「烧」进去只是第一步——相当于给单片机换了一个能说 MQTT “语言”的大脑,但它要想真正工作,还得能“找到 Wi-Fi、找到 Broker、学会说暗号”。下面是烧完之后必须再做、或者至少要确认的几件事:

环节还需要做什么没做好的常见现象
Wi-Fi 配网在固件配置文件、Web 配网页或 AT 指令里填对 SSID/密码开机后串口/日志一直 Connecting to WiFi...
Broker 信息把 MQTT 服务器 IP/域名、端口、用户名、密码写进去MQTT connect failed, RC= -2/-4/5 等错误码
Client ID / Topic 设计设唯一的 Client ID,规划要订阅/发布的主题Broker 日志提示 “client id not unique”、消息收不到
QoS、Keep-alive、SSL 证书需按实际网络状况与安全要求调时不时掉线、握手失败
业务代码写 loop() 或回调,把订阅的指令解析、把传感器数据 publish能连上但“什么都不做”

换句话说:

烧固件 → ⭕ 基础能力具备;
配置参数 + 写业务 → ⭕⭕ 才能真正“能用”。

最快的自检流程(烧完后别跳过)

  1. 先让它连上你家的 Wi-Fi — 用串口看有没有拿到 IP。
  2. 改成连本地电脑上的 Mosquitto(先不开 SSL,端口 1883),把用户名密码设成匿名,省去一堆变量。
  3. 在串口看到 “MQTT connected, rc=0”。如果这一步卡住,说明配置还没填对。
  4. mosquitto_sub/pub 做回环:ESP 发布 /hello,PC 收得到;PC 发 /cmd,ESP 串口能打印。
  5. 都通了再去换成真正的云 Broker、打开 SSL、写正式业务代码。

这样就能一步步确认“固件本身 OK ➜ 参数 OK ➜ 环境 OK ➜ 业务 OK”。


如果你已经烧好固件但连第一步都没通过,告诉我你看到的串口日志/错误码,我帮你一起排查。

问题

能连上wifi

思考

Responding in Chinese for MQTT validation

User mentioned their ESP8266 is connected to WiFi, so they're likely past the first setup step. Now, they may need help moving forward with MQTT. I'll guide them by suggesting they configure the MQTT broker settings, like the IP and port. I’ll explain how to test the MQTT connection using serial logs and tools like mosquitto_pub/sub. Also, I’ll provide commands based on the NodeMCU or Espressif AT command set for checking MQTT settings and ensuring the firmware is configured properly.

Thought for 7 seconds

回答

好,既然 ESP8266 已经成功拿到 Wi-Fi IP,下一步就是确认 MQTT 连接是否真正建立。下面给你一条最省事的“快检通道”;如果任何一步出问题,再把日志贴给我一起排:


1 分钟 MQTT 快速自检

步骤要做什么如何判断成功
① 写入 Broker 参数把 MQTT 服务器的 IP/端口/用户名/密码/ClientID 填到固件里(不同固件位置不一样,见下)参数保存后重启,串口里出现 “Connecting to MQTT…”
② 看串口握手结果接串口调试器,波特率通常 74880 或 115200,重启板子串口打印 MQTT connected, rc=0 / OK,CONNECT / CONNACK 0 等字样
③ 做回环测试在 PC 上装 Mosquitto CLI:<br>mosquitto_sub -h <brokerIP> -t /esp/test -v<br>让 ESP 执行 publish("/esp/test","hello")PC 终端马上显示 hello
④ 反向下行测试PC 端执行:<br>mosquitto_pub -h <brokerIP> -t /esp/cmd -m "LED_ON"串口里打印收到的 payload,或板载 LED 亮起
⑤ 长跑观察让它空跑 5-10 分钟,看有没有自动掉线重连串口里保持静默或偶尔心跳,无反复 “reconnect”

前三步全绿灯,就说明固件的 MQTT 功能是正常可用的。


不同固件如何填 MQTT 参数

固件类型入口/命令示例
Espressif AT 固件 ≥ v2.1串口 AT 指令AT+MQTTUSERCFG=0,1,"esp01","user","pass",0,0,""\r\r\nAT+MQTTCONN=0,"192.168.1.2",1883,0\r\r\n
NodeMCU / Luainit.lua 或 WebIDEm = mqtt.Client("esp01", 60, "user", "pass") m:connect("192.168.1.2",1883)
TasmotaWebUI → Configuration ▸ Configure MQTT依次填 Host / Port / User / Password / Client
ESPHomemy_esp.yamlmqtt: broker: 192.168.1.2 username: user password: pass

常见返回码速查

返回码/现象含义处理办法
rc = -2 / DNS failBroker 域名解析不到用 IP 测试或检查 DNS
rc = 5 / Not authorized用户名/密码/ACL 错核对账号、Topic 权限
不停 reconnectKeep-alive 太短 / Wi-Fi 波动把 keepalive 调到 60 s ↑,检查信号

如果你已经按表格设好 Broker 参数但串口里看不到 “MQTT connected, rc=0”,请把串口完整日志、所用固件名称和你发的配置命令贴出来,我再帮你定位具体问题 💪

问题

AT+MQTTUSERCFG的参数是什么

思考

Thought for 10 seconds

回答

AT+MQTTUSERCFG 命令格式

AT+MQTTUSERCFG=<LinkID>,<scheme>,<"client_id">,<"username">,<"password">,<cert_key_ID>,<CA_ID>,<"path">

作用:一次性写入 MQTT 连接必需的 8 个核心字段。设备返回 OK 即代表保存成功。Espressif Docs

参数含义典型取值备注
<LinkID>连接序号0目前仅支持单连接
<scheme>连接类型1-101=TCP;2-5=TLS;6-10=WebSocket(见下表)Espressif Docs
"client_id"MQTT Client IDesp8266-01≤256 字节。需全局唯一
"username"用户名user1≤64 字节
"password"密码pass1≤64 字节
<cert_key_ID>客户端证书 ID0仅 TLS/双向认证时用,ESP 当前只认 0
<CA_ID>CA 证书 ID0TLS 服务器验证时用,ESP 当前只认 0
"path"WebSocket 路径"/mqtt"""仅 scheme 6-10 时需要

<scheme> 对照表

协议是否验证服务器证书是否发送客户端证书
1MQTT over TCP
2TLS - 不验证
3TLS - 验证服务器
4TLS - 客户端证书
5TLS - 双向验证
6WebSocket (TCP)
7WSS - 不验证
8WSS - 验证服务器
9WSS - 客户端证书
10WSS - 双向验证

使用示例

  1. 最简单的 TCP 直连(无加密):
    text
    AT+MQTTUSERCFG=0,1,"esp01","demo","123456",0,0,""
  2. TLS 单向验证(验证服务器证书):
    text
    AT+MQTTUSERCFG=0,3,"esp01","secure","p@ss",0,0,""
  3. WSS 双向认证(常见云服务 WebSocket):
    text
    AT+MQTTUSERCFG=0,10,"ws01","iotuser","iotpass",0,0,"/mqtt"

写完后 再执行

text
AT+MQTTCONNCFG=0,60,0,"lwt","offline",0,0 // 可选:Keep-alive、LWT 等 AT+MQTTCONN=0,"broker.hivemq.com",1883,1 // 真正去连服务器

正常会看到 +MQTTCONN:0,4,... 表示已建立连接。

补充注意点

  • 整条指令 长度不得超过 256 字节;若 client_id/username/password 太长,可先用此命令占位,再分别用 AT+MQTTCLIENTID / AT+MQTTUSERNAME / AT+MQTTPASSWORD 或 “LONG” 版本写入长字段。Espressif Docs
  • 若使用 TLS,需先用文件系统指令把证书写进模组并分配到 ID 0,再在 MQTTUSERCFG 里引用。
  • 执行 AT+MQTTUSERCFG? 可随时查看当前保存的 8 个字段内容。

照着上面填完并连通 AT+MQTTCONN 后,就能进入订阅/发布阶段 (AT+MQTTSUB, AT+MQTTPUB 等)。如果还有返回码或连接问题,把日志贴出来我再帮你分析。

问题

AT+MQTTUSERCFG=0,1,"SmartLed","T1gRn3G57q","version=2018-10-31&res=products%2FT1gRn3G57q%2Fdevices%2FSmartLed&et=1956499200&method=sha1&sign=YScT2YFKeMLzTF2EelmhRmCGpsU%3D",0,0,""

ERROR

Python

python
password = "version=2018-10-31&res=products%2FT1gRn3G57q%2Fdevices%2FSmartLed&et=1956499200&method=sha1&sign=YScT2YFKeMLzTF2EelmhRmCGpsU%3D" len(password) 127

Python

python
cmd = 'AT+MQTTUSERCFG=0,1,"SmartLed","T1gRn3G57q","'+password+'",0,0,""' len(cmd) 179

思考

The issue is that the password length exceeds 64 bytes, causing MQTTUSERCFG to fail. To fix this, use a placeholder password with AT+MQTTUSERCFG, then set the long password with AT+MQTTPASSWORD. Alternatively, you could just use AT+MQTTPASSWORD directly. Since Aliyun IoT uses long passwords, consider using encoded tokens, ensuring you don't exceed 256 bytes in AT+MQTTPASSWORD. Remember to include correct quoting in the command. You can also shorten client_id or path if needed. Upgrading firmware may also solve the issue.

Thought for 39 seconds

回答

ERROR 并不是语法写错,而是参数超限

为什么超限?

官方文档对 AT+MQTTUSERCFG 有如下硬性限制 Espressif Documentation

字段最大长度
client_id256 B
username64 B
password64 B
整条指令256 B(含 AT+… 本身)

你传进去的 password

version=2018-10-31&res=products%2FT1gRn3G57q%2Fdevices%2FSmartLed&et=1956499200&method=sha1&sign=YScT2YFKeMLzTF2EelmhRmCGpsU%3D

实际长度 127 B,已经超过 64 B,所以固件直接返回 ERROR(内部错误码是 AT_MQTT_PASSWORD_IS_OVERLENGTH,但默认不会打印出来)。

正确做法:先占位,再用长版本指令写入

  1. 用一个占位密码把配置写进去

    text
    AT+MQTTUSERCFG=0,1,"SmartLed","T1gRn3G57q","x",0,0,"" OK

    这里的 "x" 只是占位,长度 < 64 B 即可。

  2. 再把真正的长密码写进来(最长 256 B)

    text
    AT+MQTTPASSWORD=0,"version=2018-10-31&res=products%2FT1gRn3G57q%2Fdevices%2FSmartLed&et=1956499200&method=sha1&sign=YScT2YFKeMLzTF2EelmhRmCGpsU%3D" OK
  3. 如果日后需要改 client_idusername 超过 64 B,同理用

    text
    AT+MQTTCLIENTID=0,"your_long_clientid" AT+MQTTUSERNAME=0,"your_long_username"
  4. 继续常规流程

    text
    AT+MQTTCONNCFG=0,60,0,"","",0,0 // KeepAlive 60 s,可选 AT+MQTTCONN=0,"broker.example.com",1883,1

其他可能踩坑的边界

项目限制超限现象
指令总长度256 B也会直接 ERROR
path 字段32 B若用 WebSocket 必须留意
Wi-Fi NTP 时间Aliyun IoT 这类“长密码”里嵌了过期时间 (et=),设备时钟偏差太大会导致登录失败

按上面步骤把长密码拆成两条指令写入即可通过,后续 AT+MQTTCONN 就能正常握手了。

问题

我这个是在串口助手发送的

思考

The user mentions sending a command via a serial assistant, and this seems to relate to an error from the previous issue with password length. They're likely wondering how to properly send multi-line commands. I think I need to clarify how to send commands correctly in the serial terminal, including the use of CR LF line endings and the order in which commands should be sent. Also, some terminals might not automatically insert CR or could alter the format, so I should be sure to mention this.

Thought for 6 seconds

回答

明白,你是在 Windows 或 macOS 用串口调试助手(SSC-OM、SecureCRT、Arduino Serial Monitor 等)直接手敲指令,对吧?
用这些工具可以完全做到,只要注意下面 3 个细节,就不会再碰到 “ERROR”:

关键点具体怎么做常见坑
1 指令必须以 CR+LF 结尾在大多数助手里把 “发送新行” 选为 CR+LF\r\n<br>如果没有这个选项,就在指令末尾手动按 Enter(它会自动附带 CRLF)。只发 LF 或只发 CR 会被 AT 固件当作不完整指令,返回 ERROR
2 先发短占位,再发长密码在发送区一次输入:<br>AT+MQTTUSERCFG=0,1,"SmartLed","T1gRn3G57q","x",0,0,""<br>→ 按 Enter,看到 OK<br>然后粘贴完整长密码:<br>AT+MQTTPASSWORD=0,"version=2018-10-31&res=products%2FT1gRn3G57q%2Fdevices%2FSmartLed&et=1956499200&method=sha1&sign=YScT2YFKeMLzTF2EelmhRmCGpsU%3D"<br>→ 再 Enter。把两条合并成一条会超 256 字节上限;或者直接把长密码塞进 MQTTUSERCFG 会超 64 字节上限。
3 关闭自动换行/插入空格许多中文 “串口调试助手” 默认在 80/120 列处给你插回车或空格来“美观显示”。请把 “自动换行” / “格式化显示” 关掉,或勾选 “发送原始数据”长字符串被自动折行 → 固件收到的其实是两条指令,自然 ERROR

🌟 一句口诀
短占位 → OK → 长密码 → OK,两次回车,每次都看见 OK 才算写入成功。


快速验证写入是否生效

  1. 发送 AT+MQTTUSERCFG?
    • 应返回你的 SmartLedT1gRn3G57q 和占位 "x"
  2. 发送 AT+MQTTPASSWORD?
    • 应完整回显那条长密码。

都正确后,再照顺序发:

text
AT+MQTTCONNCFG=0,60,0,"","",0,0 AT+MQTTCONN=0,"your.broker.ip",1883,1

串口出现

+MQTTCONN:0,4

+MQTTCONNECTED:0

就说明握手成功。


如果还是 ERROR,请再确认

  1. 固件版本 ≥ v2.1.0.0 才支持 AT+MQTTPASSWORD。先发 AT+GMR 看固件日期。
  2. 指令行总字节 ≤ 256。你的长密码 + 前缀 AT+MQTTPASSWORD=0,"" 一共约 170 字节,没问题;如果再长就要考虑用文件系统方式存证书。
  3. 确保 波特率对(74880/115200),避免乱码导致固件把引号看错。

还有疑问的话,把你在串口窗口里完整的收发日志(从你输入到返回)复制给我,我帮你逐行看。

问题

AT+MQTTUSERCFG=0,1,"SmartLed","T1gRn3G57q","x",0,0,""
busy p...
busy p...
busy p...
busy p...
ERROR

Python

python
cmd = 'AT+MQTTUSERCFG=0,1,"SmartLed","T1gRn3G57q","x",0,0,""\r\n' len(cmd.encode()) 55

思考

Explaining 'Busy P' error

The "busy p" error means the module is still processing a previous task. It can happen if the module is still connecting via Wi-Fi, or if certificate operations aren’t completed, or if data is sent too quickly. Here's how to address it:

  1. Wait 100-500ms after the last command, or until "OK" appears.
  2. If the MQTT service is still active, send AT+MQTTCLEAN=0 to release it and reconfigure.
  3. If the issue persists after reset, check if you are using a version earlier than 2.x (update if necessary).
  4. Ensure line endings—send "0D 0A" only once.

Lastly, try sending a simple "AT" command, and if "busy p" persists for 2 seconds, there may be a deeper issue.

Thought for 1m 23s

回答

busy p… 的含义是 “AT 固件正在处理之前的事务,目前拒绝接收新指令”。这是 ESP-AT 返回的一种系统消息,而不是语法错误。Espressif Docs
出现这一行再跟 ERROR,通常有以下几种原因,对应的解决办法也不一样——

场景触发原因快速排查 & 解决办法
① 前一条指令还没结束就又发了一条串口助手把 CR/LF 又插了一次,或者脚本循环过快- 在助手里把“自动换行/自动发送新行”关掉,只保留 \r\n 一次<br>- 手动:** 打一条指令 → 等看到 OK/ERROR → 再发下一条**(间隔 ≥100 ms)fanmimi.com
② 模块正自动重连旧的 MQTT 会话之前配置过 AT+MQTTCONN,现在还在后台尝试握手复位或干净释放:<br>```text
AT+MQTTCLEAN=0 // 断开并释放资源
AT+RST // 或直接硬件复位
// 出现 ready 后再重新发配置
text
| **③ 固件版本太老,MQTT 命令已被识别但执行异常** | 早于 **AT v2.x** 的 ESP8266 固件没有完善的 MQTT 栈 | ```text AT+GMR // 查看版本 ```<br>若版本低于 2.0.x,请刷入 **带 MQTT 功能的 v2.2.0 或更新版 BIN**,再重试。[CSDN Blog](https://blog.csdn.net/weixin_54781965/article/details/137071662) | | **④ 供电/波特率问题导致解析超时** | 3.3 V 电流不足或波特率设置错 | - 确认 3.3 V&ge;300 mA,稳压芯片有余量<br>- ESP-AT 默认 115200 bps;上电日志是 74880 bps | --- ## 建议的“零报错”流程 1. **完全复位一次** ```text AT+RESTORE // 恢复出厂参数(如不想清 NVS 可跳过) AT+RST // 软复位

等串口只剩 ready,且 无 busy p… 输出后再继续。

  1. 一次写入 8 个基础字段(先用短占位密码,避免超长错误)

    text
    AT+MQTTUSERCFG=0,1,"SmartLed","T1gRn3G57q","x",0,0,""

    → 返回 OK

  2. 单独写⻓密码

    text
    AT+MQTTPASSWORD=0,"version=2018-10-31&res=products%2FT1gRn3G57q%2Fdevices%2FSmartLed&et=1956499200&method=sha1&sign=YScT2YFKeMLzTF2EelmhRmCGpsU%3D"

    → 返回 OK

  3. (可选)检查是否写入成功

    text
    AT+MQTTUSERCFG? AT+MQTTPASSWORD?
  4. 继续 AT+MQTTCONN … 连接服务器,随后做订阅/发布测试。

只要步骤 ① 后串口不再出现 busy p...,后续配置与连接就会顺利通过;若 刚重启就不停输出 busy p…,基本可以断定还有旧 MQTT 会话未清理或固件版本不支持,按表格 ②/③ 处理即可。祝调通!

问题

还是不行

思考

Debugging further

They’re still getting the same error (busy/ERROR) after trying our suggestions. We might need additional info like firmware version, earlier commands, and more details on the environment or power supply stability. We should guide them step by step, asking for logs, the AT+GMR output, or whether the issue persists after a reset. We can suggest fine-tuning things like flow control, disabling echo, or trying different delays between commands. Maybe exploring firmware updates could help—I'll provide the official link for that too!

Thought for 10 seconds

回答

busy p… + ERROR 一直出现,说明 ESP8266 里的任务始终占着 MQTT 资源,新的 AT 指令根本来不及执行。要把“忙”状态解除,必须先搞清楚到底是谁在后台占线。下面给你一份彻底排障脚本(一步都别跳),并请你把 粗体步骤输出的完整串口日志 贴回来,我再帮你定位:


A. 先确认固件与硬件都正常

  1. 硬件最小系统

    • 3 V3 稳压≥300 mA、GND 共地、CH_PD 拉高。
    • 波特率 115 200 8N1;开机自检信息如果是乱码,多半是波特率错或供电抖。
  2. 查看固件版本

    text
    AT+GMR

    请复制贴出完整返回。ESP-AT v2.1.0 及以上才支持分条写长密码。


B. 把“一直忙”的 MQTT 任务彻底停掉

整板重新上电 → 等出现 ready立刻 重复执行下列 3 条指令(每条都要拿到 OK,中间不要插别的):

text
AT+MQTTCLEAN=0 // 若返回 ERROR 忽略 AT+RESTORE // 恢复出厂配置 AT+RST // 软复位,看到 ready 停止发送

多数情况下,busy p… 到这里就消失了;如果复位后仍然循环刷 busy p…,说明固件有 BUG 或闪存坏数据——直接 重新烧写最新版 ESP-AT(含 MQTT)整套 BIN 会最快解决。


C. 按“最短指令”方式重建连接

  1. 重新连 Wi-Fi(确认返回 WIFI CONNECTED / GOT IP

    text
    AT+CWJAP="你的SSID","你的WIFI密码"
  2. 一次写 8 个字段(用占位密码)

    text
    AT+MQTTUSERCFG=0,1,"SmartLed","T1gRn3G57q","x",0,0,""
  3. 写入长密码

    text
    AT+MQTTPASSWORD=0,"version=2018-10-31&res=products%2FT1gRn3G57q%2Fdevices%2FSmartLed&et=1956499200&method=sha1&sign=YScT2YFKeMLzTF2EelmhRmCGpsU%3D"
  4. 检查是否写进去了

    text
    AT+MQTTUSERCFG? AT+MQTTPASSWORD?
  5. 真正去连 Broker(先用本地无证书 TCP 试验)

    text
    AT+MQTTCONN=0,"broker.hivemq.com",1883,1
    • 成功:看到 +MQTTCONNECTED:0OK
    • 失败:会返回 +MQTTCONN:0,<err>,把整个行贴给我。

D. 如果仍旧 busy p…,请回传以下信息

  1. 上电后从第一行开始的全部串口输出(含 rst causeready、任何 busy p…)。
  2. 执行 AT+GMR 的结果
  3. 执行上面 C-1 ~ C-5 时每一步输入与返回
  4. 供电方案(USB-TTL 模块型号、电源芯片或开发板型号)。

我会据此判断是:

  • 旧版固件的 MQTT 内存泄漏/死锁(需要升级);
  • 闪存配置区损坏(AT+RESTORE 无效,需 erase_flash 重刷);
  • 波特率或供电不稳让 AT 解析出错;
  • 还是其它更隐蔽的问题。

把日志贴出来,我们一步步把锅揪出来 👍

问题

AT version:1.2.0.0(Jul 1 2016 20:04:45)

SDK version:1.5.4.1(39cb9a32)

Ai-Thinker Technology Co. Ltd.

v1.5.4.1-a Nov 30 2017 15:54:29 刷了mqtt固件库还是这个正常吗

思考

Thought for 57 seconds

回答

不正常。
你的模组根本没刷上带 MQTT 的新版固件,而是仍在跑 2016 年的 Ai-Thinker AT 1.2(Non-OS),这套固件里压根儿没有 AT+MQTT... 指令,所以只要你发这些指令就会出现 busy p…ERROR

关键信息说明
AT+GMR 回显AT version:1.2.0.0 (Jul 1 2016)<br>SDK version:1.5.4.1 … —— 这是 老版 Non-OS AT,最后一次更新是 2017-11-30
MQTT 命令首次出现官方 ESP-AT ≥ v2.0 才加入 AT+MQTTUSERCFG/CONN/... 等指令Espressif Documentation CSDN Blog
最新支持 ESP8266 的版本ESP-AT v2.2.2.0 (2024-03-26),zip 包里已带好 MQTT 功能GitHub

正确做法:彻底擦写,再刷「带 MQTT 的 ESP-AT v2.2」

下面以 2 MB Flash 的常见 ESP-12/ESP-WROOM-02 为例;如果你是 1 MB / 4 MB 芯片,只要换成对应的 factory.bin 即可。

1 . 准备文件

  1. 到 GitHub Releases ▸ v2.2.2.0_esp8266 页面下载
    ESP-WROOM-02-AT-V2.2.2.0.zipGitHub
  2. 解压后找到
    factory/ESP8266_WROOM-02.bin(一个约 1.1 MB 的整合包)。

2 . 擦除整片 Flash

bash
esptool.py --port COM3 --baud 460800 erase_flash

必须先 erase,否则旧固件残留的 NVS 区会继续把 MQTT 任务拉起来,导致你又看到 busy p…

3 . 烧录新版固件

bash
esptool.py --port COM3 --baud 460800 \ write_flash --flash_mode dio --flash_freq 40m --flash_size 2MB \ 0x0 factory/ESP8266_WROOM-02.bin
  • --flash_size 改成 1MB / 4MB 视你的模块而定。
  • 用 Windows 可换成 ESP Flash Download Tool,把 factory/…bin 选到地址 0x00000 即可,其他地址留空。

4 . 首次复位后自检

  1. 串口应打印
    text
    ready AT version:2.2.2.0(…) SDK version:...
    表示固件真正换新。
  2. 发送 AT+CMD 可以看到完整指令列表,其中就包括
    AT+MQTTUSERCFG, AT+MQTTLONGPASSWORD, AT+MQTTCONN, …
  3. 再按之前的 “短占位 → 长密码” 流程配置 MQTT,一切都会正常回复 OK

常见踩坑提醒

问题处理
UART 引脚变了?ESP-AT v2.x 默认仍然用 UART0(GPIO1/3),与你当前接线一致;只有 ESP32 系列才改到 GPIO15/13。
1 MB 芯片没官方包?在 release/v2.2.0.0_esp8266 分支的 CI Artifact 里找 esp8285-1MB-at,里面同样有 factory.bin 可烧Espressif Documentation
busy p... 依旧说明你没擦干净或 USB 供电不足;先 erase_flash,再确保 3.3 V ≥ 300 mA。
想自定义分区/证书别用 factory.bin,而是按包内 download.config 多文件烧录,或者自己编译。

结论
看到 AT version:2.2.x.x 并能执行 AT+MQTTUSERCFG 才算真正“刷上 MQTT 固件”。只要一步:擦干净 ➜ 烧官方 ESP-AT v2.2 的 factory.bin,你的问题就能解决。祝刷新顺利!

问题

烧录完mqtt固件后,版本没有变化正常吗

思考

Citing correct flashing process

It seems like the user’s flashing didn’t work as expected since the version didn’t change. This is unusual and suggests the firmware flash didn’t fully succeed—likely still running the old AT version 1.2. To fix this, the user should erase the flash, ensure the correct binary file and board are selected, and verify the flashing address. I’ll include references to official documentation and release notes for version 2.2, which includes MQTT support, to explain the differences and provide proper guidance.

Thought for 20 seconds

回答

不正常。
刷入真正带 MQTT 功能的 ESP-AT 新固件后,AT+GMR 一定会显示新的 AT version ≥ 2.x(例如 AT version:2.2.2.0(…2025-03-26))——因为 MQTT 指令只在 2.x 系列才加入。仍然停在 AT version:1.2.0.0 说明旧固件仍在 Flash 的启动分区里,新的镜像根本没被 MCU 启动Espressif Documentation GitHub


常见原因 & 对策

类别典型原因如何验证解决办法
烧录步骤• 只写了 user1.bin 等“增量包”<br>• 地址没对准 0x0000<br>• Flash 未 erase用 flasher 日志确认是否真写到 0x0000,并且写入大小≈1 MBesptool.py erase_flash → 把 factory/ESP8266_WROOM-02.bin 写到 0x0(或用官方 Flash Download Tool 勾选 “Factory”) Espressif Documentation
启动 fallback校验失败 → Bootloader 退回旧映像上电时 74880 bps 日志会提示 “invalid head”确保 --flash_mode dio --flash_freq 40m --flash_size 与芯片实际匹配;写完务必掉电重启
未进下载模式GPIO0 没拉低,实际上根本没写进去烧录时看不到 “Writing at 0x000000…”烧录前:GPIO0→GND、EN→3V3,再上电;烧完松开 GPIO0
容量不匹配用 2 MB 镜像烧到 1 MB 芯片烧录日志正常,但复位进不了系统换成 release 页面里 esp8285-1MB-at 或自己编译 1 MB 版 Espressif Documentation
电源/串口问题烧录 OK,但上电电压掉、波特率错复位后乱码、频繁重启3.3 V≥300 mA,波特率 115200 8N1

推荐的“零歧义”刷机流程

bash
# 1. 擦除整片 esptool.py --port COM3 erase_flash # 2. 烧入官方一体化 factory 镜像(以 2 MB 模块为例) esptool.py --port COM3 --baud 460800 \ write_flash --flash_mode dio --flash_freq 40m --flash_size 2MB \ 0x0 ESP8266_WROOM-02-AT-V2.2.2.0/factory/ESP8266_WROOM-02.bin

换 1 MB / 4 MB 模块时只改 --flash_size 并使用对应的 factory.bin。

烧完 断电 → 恢复 GPIO0,再上电:

text
ready AT version:2.2.2.0(...) SDK version:3.x

此时 AT+MQTTUSERCFG, AT+MQTTCONN 等命令均能正常返回 OK,之后再按“占位密码 → 长密码”方式配置 MQTT。GitHub


小结

  • 版本号不变 ≠ 正常 —— 代表 MCU 依旧跑旧固件。
  • 重点检查:是否 erase,写到 0x0,Flash 大小参数正确,烧录日志无错,刷后掉电重启。照着上述步骤,再跑一次就能看到新版本。祝你刷新成功!

问题

烧录好几次版本号都没变

思考

Identifying flashing issues

To troubleshoot the flashing problem, I should focus on key root causes:

  1. The module may not be in download mode, preventing flashing.
  2. The wrong binary could be used.
  3. The flasher tool might be outdated.
  4. If using two partitions, the boot partition may not have been overwritten.

I’ll guide the user through several verification steps. First, use esptool to check connection and ensure proper GPIO0 and RST settings. Verify flash with “write_flash --verify”, and check the new header by reading the first 0x100 bytes. If still failing, I'll ask for the flasher log.

Thought for 26 seconds

回答

连续刷了几次版本号仍停在
AT version:1.2.0.0 (Jul 1 2016) → 固件实际上一次都没有被写进去。

99 %的情况都是“烧录流程某一步没真正执行”,而不是镜像本身有问题。下面按“排线 → 擦除 → 写入 → 验证”给你一个零死角的检查表,照做一次基本就能找出卡点。


1 . 先确认“真的进了下载模式”

必须状态典型接法
GPIO0 → GND(低电平)把模块的 GPIO0 短接到 GND,再给板子上电或按 RST
EN/CH_PD → 3 V3始终保持高电平
TX ↔ RX 交叉接 USB-TTL(3 V3 级)波特率先设 115 200 8N1
供电 ≥ 300 mA、3 V0 – 3 V6手机充电器 + AMS1117 很容易掉压,最好用稳压模块

自测:GPIO0 拉低上电后,用

bash
esptool.py --port COM3 flash_id

能返回 Manufacturer, Device ID 就证明你已在“下载模式”。如果连这一条都握不到手,线/供电肯定有问题。


2 . 彻底擦除旧固件

bash
esptool.py --port COM3 erase_flash

看到

Chip erase completed successfully in …

才算真正清空。没先 erase_flash,旧 1.2 固件就会继续保留(因为它仍然在 0x0000 区)。


3 . 用“一体化 factory.bin”写回 0x0000

以 2 MB(16 Mbit)Flash 的 ESP-12F / WROOM-02 为例:

bash
esptool.py --port COM3 --baud 460800 \ write_flash --flash_mode dio --flash_freq 40m --flash_size 2MB \ 0x0 ESP8266_WROOM-02-AT-V2.2.2.0/factory/ESP8266_WROOM-02.bin
  • flash_size 按实际芯片换成 1 MB / 4 MB。
  • 用官方 Flash Download Tool 也行,只勾一行:地址 0x00000, 文件选 factory.bin,记得先勾 “Erase Flash”
  • 烧完 断电松开 GPIO0 → 再上电。

4 . 开机后立刻验证

  1. 上电日志(74880 bps)应只有几行 Boot 信息,再出现 ready
  2. 打 115 200 bps 执行
    text
    AT+GMR

    成功:

    text
    AT version:2.2.2.0(…2024-03-26) SDK version:3.x.y

    失败:还显示 1.2 或直接乱码 → 回到步骤 1 / 2 重查。


5 . 如果还是老版本,逐项对照以下 Checklist

排障点现象处理
① 没进下载模式esptool.py flash_id 报 “Failed to connect”重新拉低 GPIO0,再复位;部分开发板得按住 FLASH 键上电
② 写入地址错烧录日志里地址不是 0x000000写入命令一定要 0x0 factory/…bin
③ Flash 模式/频率不符上电 74880 日志出现 invalid head 0x??--flash_mode 改成 dout 再试;个别旧板子只认 dout 40m
④ 容量不符烧录 OK,复位后死循环重启1 MB 芯片却烧 2 MB 镜像;换下载页里 esp8285-1MB-at 的 factory.bin
⑤ 供电掉压烧录时一到 50 % 就断,或复位后花屏给 3 V3 端并个 470 µF 电容,或改用 5 V→3 V3 DC-DC

6 . 让烧录“可验证”

  • 写入时加 --verify
    bash
    esptool.py --port COM3 write_flash --verify … 0x0 factory.bin
    写完会自动把 Flash 读回校验。
  • 手动读回首 64 字节
    bash
    esptool.py --port COM3 read_flash 0x0 0x40 header.bin hexdump -C header.bin
    看到 E9 04 00 00 这样的新头标,就说明新镜像真在 0x0 了。

资料出处


下一步

  1. 先确保 AT+GMR 显示 2.x
  2. 再按“占位密码 → AT+MQTTPASSWORD”配置 MQTT。
  3. 若仍卡在旧版本,请把完整烧录日志上电 74880 bps 输出贴上来,我帮你逐行看。祝你一次点亮!